Key points of connector connection: contact area

Author:Jasper Release time:2025-06-06 225 Views


The resistance value of the contact point/contact resistance value is important

Wire harness, board installation, assembly The final operation is mating. 

The contact plays an important role in the mating process, and the resistance 

value on the contact is also important.


The so-called mating of the connector refers to the matching process between 

the connectors. This assembly work is different from the manufacturing/wire 

harness/board installation manufacturers. It is performed by professional assembly 

manufacturers. Even if it is handled within the company, it is handled by a 

department specializing in assembly work. As can be seen, the mating of the 

connector is a work that requires professional skills and knowledge.


The role of the contact area is very important for the mating between connectors, 

but the quality of the contact area is judged based on the stability of the contact 

resistance value. In the connector catalog and manual, "contact resistance value"

 is always listed as "contact resistance value".


To stabilize the contact resistance value

If the contact resistance is unstable, the power cannot be transmitted correctly. 

Therefore, each connector manufacturer has put a lot of effort into the design 

of the connector to stabilize the contact resistance value.


[Coating measures] Increase contact pressure


The contact part of the terminal has various shapes, but they are all metal, so an 

oxidized coating will be formed. By increasing the contact pressure, the terminal 

contacts can break through the oxide film and transmit power correctly.


[Anti-corrosion measures] Contact plating


The metal surface of the terminal will oxidize and corrode over time, and then 

become non-conductive. To prevent non-conduction, appropriate plating is 

performed on the contact area and welding area of the terminal to ensure a 

long-term stable contact resistance value.


[Vibration measures] Fixed contacts


Various devices, including automotive equipment and industrial equipment, 

vibrate. This vibration causes the terminal contacts to wear and produce defects, 

but by fixing the connector contacts, the adverse effects caused by vibration can be reduced.


[Preventing foreign matter and dust] Multiple contacts


Some equipment is used in an environment with dust and dirt. For equipment 

used in such an environment, a connector with a multi-contact structure can be 

used to maintain the contact resistance value even if foreign matter enters.


How to select the type of terminal plating

In order to stabilize the contact resistance value, the contact area needs to be 

plated, but many people ask how to select the type of plating. If you are confused, 

please select the type of plating based on the equipment's usage environment and 

circuit current. If gold plating is used throughout, the contact resistance will be 

very stable, but if tin plating or gold plating is appropriately selected, cost will be saved.