The resistance value of the contact point/contact resistance value is important
Wire harness, board installation, assembly The final operation is mating.
The contact plays an important role in the mating process, and the resistance
value on the contact is also important.
The so-called mating of the connector refers to the matching process between
the connectors. This assembly work is different from the manufacturing/wire
harness/board installation manufacturers. It is performed by professional assembly
manufacturers. Even if it is handled within the company, it is handled by a
department specializing in assembly work. As can be seen, the mating of the
connector is a work that requires professional skills and knowledge.
The role of the contact area is very important for the mating between connectors,
but the quality of the contact area is judged based on the stability of the contact
resistance value. In the connector catalog and manual, "contact resistance value"
is always listed as "contact resistance value".
To stabilize the contact resistance value
If the contact resistance is unstable, the power cannot be transmitted correctly.
Therefore, each connector manufacturer has put a lot of effort into the design
of the connector to stabilize the contact resistance value.
[Coating measures] Increase contact pressure
The contact part of the terminal has various shapes, but they are all metal, so an
oxidized coating will be formed. By increasing the contact pressure, the terminal
contacts can break through the oxide film and transmit power correctly.
[Anti-corrosion measures] Contact plating
The metal surface of the terminal will oxidize and corrode over time, and then
become non-conductive. To prevent non-conduction, appropriate plating is
performed on the contact area and welding area of the terminal to ensure a
long-term stable contact resistance value.
[Vibration measures] Fixed contacts
Various devices, including automotive equipment and industrial equipment,
vibrate. This vibration causes the terminal contacts to wear and produce defects,
but by fixing the connector contacts, the adverse effects caused by vibration can be reduced.
[Preventing foreign matter and dust] Multiple contacts
Some equipment is used in an environment with dust and dirt. For equipment
used in such an environment, a connector with a multi-contact structure can be
used to maintain the contact resistance value even if foreign matter enters.
How to select the type of terminal plating
In order to stabilize the contact resistance value, the contact area needs to be
plated, but many people ask how to select the type of plating. If you are confused,
please select the type of plating based on the equipment's usage environment and
circuit current. If gold plating is used throughout, the contact resistance will be
very stable, but if tin plating or gold plating is appropriately selected, cost will be saved.