Connectors are a common part of almost any electronics project. Knowing what connectors are available and
what specifications to keep in mind is important during the design process. You don’t want to find out near the
end of a project that you need to add something and adjust the project to accommodate this change, which
would cost you time and money.
If you are selecting a connector for your project, there are some considerations you need to take into account
when specifying the connector requirements. Some common questions include:
Number of Contacts
In many cases, the number of contacts required for a connector is known. However, sometimes other needs of
the overall application and the availability of individual connectors will ultimately affect the specifications of the connector selected.
In addition, the power that the connector needs to handle needs to be further considered as this will affect the
connector selected. As the power capacity of connectors continues to increase, you will find that the total number
of contacts for any package/shell size will decrease. This is due to the need for more space for larger wire gauges
and/or higher voltages. Some manufacturers try to increase the voltage rating by adding more isolation between
contacts and increasing the overall "distance" that the arc has to travel from one contact to another. In addition,
some connectors have ground contacts built into the remaining contacts. These contacts are longer than the other
contacts in the connector and are used to reduce/eliminate arcing between the two mated/unmated connectors.
In addition, the following points should be kept in mind and considered during the connector selection process:
How many connectors and contacts do you need or want to use to get power into/out of the housing?
Common contact combination types for connectors
Power contacts only
Signal contacts only
Power and signal contacts
Signal + ground contacts
For projects where only one connector can be used, a slightly larger connector may be required to accommodate all the contacts.
If the signal and power contacts are separate, the required mounting space will increase. However, this may be a
general layout requirement for the application, or the function of the application may require the two contacts to
be separated.
Mounting Types
Projects also need to consider how you want to mount each connector. Several mounting types are listed below
with links to examples.
PCB Pin Through Hole - where the terminating pins of the connector are used to mount/secure the connector to
the circuit board through holes in the circuit board.
Circular Connectors
D-Sub Connectors
Rectangular Connectors – Headers, Male Pins
Rectangular Connectors – Headers, Female Sockets
PCB Surface Mount - Where the terminating pins of the connector are used to mount/secure the connector to the
circuit board, with the pins resting on contact pads on the surface of the circuit board.
Circular Connectors
D-Sub Connectors
Rectangular Connectors – Headers, Male Pins
Rectangular Connectors – Headers, Female Sockets
Panel Mount - Where a hole is made in a surface or panel and the connector is passed through or placed against the hole.
Since the connector is mounted to the board behind the panel, the securing method can be threads and nuts or directly fixed in place.
Rectangular Connectors – Free Hanging, Panel Mount
Circular Connectors
Circular Connectors – Housings
Free Hanging/Cable Mount - The connector is mounted/mounted to the cable it terminates on.
Circular Connectors
Circular Connectors – Housings
Rectangular Connectors – Housings
Board/Card Edge/Cave Mount - For card edge, the termination is close to the edge of the board and in many cases the
connector is modified for use at the edge. For a hole-in-the-board, the situation is similar because it is near the edge
of the board. However, a portion of the board has been holed so that the connector has a low profile. Both types of
mounting are intended to achieve a flatter overall board profile. They can also be used when there is a lack of available
space on the board or for other design requirements.
USB, DVI, HDMI Connectors
Coaxial Connectors (RF)
Through-Board Mount - Similar to a hole-in-the-board mount, but the difference is that this type of connector is not often
found near the edge of the board. They are also similar to panel mount connectors because they are mounted through a
hole in the board. Some terminate through a hole in the board and are soldered on the same side that the connector mates,
while others are surface mounted to the side of the board they are mounted on (opposite the side that the connector mates).
Examples of this type of connector are:
Terminals – Wire-to-Board Connectors
Solid State Lighting Connectors
Rectangular Connectors – Board-mount, Direct Wire-to-Board
Mounting Methods
The terms “mount” and “termination” are often used interchangeably, but it is important to remember that they are not always
interchangeable and there is a difference between the two. Mounting refers to how the entire project and connector as a whole
is connected/fixed/attached. Termination refers to how the electrical connection is made. Through-hole and surface mount in
most cases refer to connectors that can be mounted and terminated in a specific manner (see Termination Methods below).
The following are possible examples of mounting, mating, and termination combinations:
Connector 1
Panel mounted
Terminated to board using right angle surface mount contacts
Connector 2 mating to connector 1 is
Free hanging connector
Threaded termination
Termination Methods
What termination method is required for each end or connection? If there is no specific type requirement stated up front, the
termination method can be based on personal preference. However, some applications may require a specific type of termination.
Solder Termination - For connectors, this termination method works well in many applications. However, for applications in
high temperature areas, more mechanical termination methods may need to be considered. Soldering can be used for both
wire termination and board termination connections. Therefore, this type of termination includes a variety of connector
soldering methods. Through-hole soldering and surface mount as described above, describe a type of mounting and termination.
Typical connector solder termination.
Through-hole soldering - The connector termination side has pins that pass through pre-punched holes in the board and
usually has copper pads on the opposite side of the board from the through-hole connector access side. Once in place, the solder is secured.
This board-to-board/board-to-cable connector is connected to the PCB using through-hole soldering.
Surface-mount termination - The connector pins and mounting pads are on the same side of the PCB. The connector can be
placed and soldered in place manually or reflow and wave soldered in place. Note that some board/card edge connectors
are also surface-mount types.
This board-to-board/board-to-cable connector is surface-mount soldered to the PCB.
Crimp - This type of termination is very robust and reliable and can be used to terminate wires. However, it depends on the
quality of the crimp and proper installation in the contact housing. To achieve a quality crimp and overall connection, you
need to ensure that you use the correct contact for the housing and the correct crimping tool. Tool selection is an important
step for these contacts. If final quality is not a concern, then other existing tools or lower cost devices may be used. However,
if final quality is a concern, then it is necessary to use the manufacturer's recommended tooling, the associated wire preparation
steps, and any crimp quality data provided by the manufacturer for post-crimp inspection (note: not all inspections are required,
just sampling verification is sufficient). If the tooling and correct steps are not used, and the connection is made incorrectly,
most manufacturers of these connectors will not provide support or warranty.
Example of a contact crimped to a stripped wire conductor.
Press-in/Poke-in -
This type of termination can be either a permanent or releasable termination, and is equally reliable and robust. However,
if used in a high vibration environment, it is recommended that the connector be checked for vibration resistance.
This type of termination typically requires only stripping the wire and then pressing it into the connector, or actuating the
locking lever to the unlocked state, inserting the wire, and moving the locking lever to the locked state.
For the type that can release the wire, some mechanism may be built into the connector, or a tool such as a flat blade
screwdriver may be required to press into a slot in the housing.
This board mount connector is terminated with a stripped wire that is pressed into the lower opening. In this case, a tool
can be used to release the wire if needed.
This free hanging connector terminates the stripped wire by pressing/inserting the wire into one of the ends. For this
particular type of connector, a twisting and pulling action can release the wire.
Screw Terminals - This type of termination is used on a variety of connector types and can be used in different ways.
Here are examples of different types of screw-terminated terminals:
281-2879-ND | 609-4193-ND | 732-2759-ND | 281-3218-ND | 609-3832-ND | WM7477-ND | 732-10091-ND | ED2947-ND
| 1776293-3-ND | WM5751-ND | WM5761-ND
Examples of connectors that use screw-terminated wires
Wrap-around
An example would be the CWN-370-50-0000. This type of connector can be used in wrap-around applications.
The CWN-370-50-0000 is designed to be mounted to a PCB first, soldered in place, and then wrapped around.
These connectors are not necessarily used in products that will be put into mass production. They are used for
high frequency end products and low volume prototypes.
The following links show information on wrapping practices.
These are examples of connectors that use a wrapping method to terminate wires.
Press-Fit - This can be a solderless termination type. Therefore, this method can help reduce the overall cost of a project.
Note that press-fit terminations are generally not designed to be used with soldering. However, if for some reason you
need to solder this type of connector, be aware that doing so will affect the part and the manufacturer may not provide
any support for issues that arise. It is recommended that you consider carefully and test before soldering these connectors.
Additionally, this termination type will come with tooling available to ensure that the connector is inserted smoothly and fully
seated. It is recommended that you use the tooling listed by the manufacturer. If the manufacturer does not list tooling,
you may need to contact the manufacturer directly and they may need to discuss your application requirements with you.
ELECTROWING's Press-Fit Technology Brief is an excellent reference for this technology type.
These are examples of connectors that can terminate to pre-set holes on the mounted circuit board, both through-hole and press-fit types.
Environmental Considerations
If the application environment is relatively normal and no extremes are expected, then almost any connector will be suitable
for the specific needs specified. But when designing projects for harsh environments—where the connectors may be subject to
vibration, motion shock, shielding, environmental ingress, oils, solvents, or any number of chemicals and corrosion—then these
features need to be kept in mind during the selection process.
Vibration and Dynamic Shock
For connections inside an enclosure, select connectors with additional features such as mounting bosses and other larger pads/pins.
Omron's XH5 product brief provides some options that include just these two features. Starting on page 3, the document provides
illustrations of the connectors and the mounting patterns that can be used with each connector to take advantage of the mounting features.
For connections that need to enter or exit an enclosure, there are quite a few options for any particular type of connector.
The specifications of the connector being considered should be reviewed to see if it has been tested and is appropriate for the shock
and vibration levels that the project is expected to encounter.
Shielding
When ambient magnetic noise is a concern or is a regular problem, the connector should be shielded.
For connectors that do have shielding, it may be necessary to consider whether only specific parts need shielding or (in the case of cables)
whether the entire path needs to be shielded uniformly. Take Ethernet cables, for example. If the environmental conditions are benign,
some basic Ethernet cables and 8-position modular connectors can be used. However, as the environmental magnetic noise increases,
shielded modular connectors and Ethernet cables need to be considered/used.
Wurth Electronik's Effective EMI Shielding Concepts application note is a good reference for information on shielding issues.
For oils, solvents, or any type of chemicals and corrosion, it may not be possible to find options that meet other specifications and are
rated for such environments. In some cases, if the rating is not met, it may be necessary to communicate with the manufacturer to
obtain a connector variant that can be used in such environments.
Here is some information on such environmental hazards:
Harsh Environment Connector Selection Guide, Amphenol
Electrochemical (Electrolytic) Corrosion, Samtec
Do Connectors Need Ingress Protection?
Ingress protection ratings indicate how well a connector prevents solids/dust and moisture/water from entering its protected area.
If this is a major consideration, it should be considered during the connector selection process, eliminating all other options that do
not meet the ingress protection requirements.
Ingress protection rating format IPX1X2YZ
IP = Ingress protection
X1
0 - No special protection
1 - Protection against solid objects over 50 mm, such as accidental contact by a human hand
2 - Protection against solid objects over 12 mm, such as fingers
3 - Protection against solid objects over 2.5 mm (tools and wires)
4 - Protection against solid objects over 1 mm (tools, wires and thin wires)
5 - Limited protection against ingress of dust (no harmful deposits)
6 - Completely dust-tight
X2
0 - No protection
1 - Protection against vertically falling water drops, such as condensation
2 - Protection against direct water spray at a maximum of 15° from vertical
3 - Protection against direct water spray at a maximum of 60° from vertical
4 - Protection against water spray from all directions - Limited ingress allowed
5 - Protection against low-pressure water jets from all directions - Limited intrusion
6 - Temporary flooding protection, such as for ship decks - Limited intrusion permitted
7 - Protection against immersion from 15 cm to 1 m
8 - Long term pressurized immersion protection
Y and Z
Uncommonly used
Can be used to represent multiple specifications. The following information helps define Y and Z
Here is what I got from the engineering team at Switchcraft - "IP is coded in IEC 60529