Two-point contact connector
What is a two-point contact?
Two-point (or multi-point) contact is an option to improve the reliability of connector connection,
and various structures have been designed. As the name implies, it is a connector that has "2" contacts
connected at a time, and is a technology that realizes "as long as one of them is connected" = redundant
connection. This reduces the risk of problems during mating and the risk of temporary disconnection due
to vibration. In addition, satisfying certain structural conditions can also play a role in removing foreign matter.
On the other hand, there are also weaknesses or problems as a two-point contact point. We discussed this a
little in "What is a connector?", but we will explain it in more detail here.
Main two-point contact structure
As mentioned above, various structures for two-point contact have been designed and put on the market, but
they can be roughly divided into four types.
①Contacts are arranged vertically
②Contacts are arranged horizontally = broken items
③Structure in which male contacts (plugs) are sandwiched between female contacts (sockets)
④They have contact points with each other and combine to form two-point contact.
Various two-point (multi-point) contact structures can generally be said to be derived from these four types.
For example, coaxial connector contacts can also be considered as multi-point contacts that rotate 360°,
but this can also be said to be a derivative of ③.
Conditions for correctly providing redundant connections
Any of the above four structures requires "independent springs" to provide redundant connections.
The right figure is an example of a very simple foreign body riding figure, but on the contact point where
the spring is not independent, "both points are lifted at the same time", so the contacts of the two points
also fall off synchronously. This not only inhibits the mating of foreign bodies, but also cannot be expected to
connect redundancy if the two contacts move synchronously, such as due to momentary interruptions caused by vibration.
Regarding ① to ④ in the previous section, ③ and ④ do not hold unless the springs are independent in the first place.
For example, when the springs at ① or ② are not independent, it may be due to the influence of local defects on
the other side, or the wiping effect of soft foreign matter (①), or the influence of ejection mechanisms such as tire grooves.
Although reliability can be improved in aspects such as (②), the independence of the spring is necessary to ensure accurate
redundant connections. In principle, all 2-point contacts provided by IRISO have independent springs.
For example, although it is rare, we also provide compression terminals with two independent spring contacts.
Two-point contact in series that effectively removes foreign matter
This is the same as the content of "What is a connector?" As you can clearly see by playing the video below, the two-point
contact in series has the effect of wiping off foreign matter. This effect can only be expected with the series type
① of the categories ① to ④ in the previous section. When adopting 2-point contact, IRISO emphasizes this foreign matter
removal effect and uses the series type as its main product. In fact, we have helped many customers solve mating problems
caused by foreign matter.
Issue of 2-point contact: Affinity with high-speed transmission
So, is the two-point contact suitable for all uses? It does have some difficult aspects. This is the issue of compatibility with high-speed
transmission. One is that the terminal shape becomes complicated and it is difficult to ensure impedance matching (Question 1).
For more information, if you are interested, please refer to the IRISO technical note "Are the requirements of 'floating' and
'high-speed transmission' contradictory?".
Another issue is that it is more serious if this happens, but even if the initial characteristics are good, it is also a problem that
"if one side of the two-point contact falls off, the performance will not appear" (Question (2)). The contact point on the departure
side becomes a state called "stub" where high-frequency signals cause resonance and good transmission cannot be maintained.
Although it should ensure redundancy by having two contact points, if it exceeds a certain area, it will "take risks at more points".
There is also a difficulty that it cannot be found by DC/low-frequency signal inspection when the device is started. These problems
become apparent depending on the connector size and specific design, but there seems to be an example where they become
apparent from exceeding 10Gbps. This phenomenon on the high-frequency side is difficult to reproduce by actual verification,
so the risk can be reduced by confirming the performance change when one side is deviated by electromagnetic field simulation
as a preliminary verification. On the other hand, if the rate of "high-speed transmission" is lower than a certain level, it can be
expected to improve reliability (Figure). First of all, in order to bring the solution to problem (1) to this field, it is necessary to
make a precise design, so this is also a problem that is currently manifested only in limited places.
At present, IRISO products have not yet released 2-point contact connectors for the area where this problem becomes apparent
(10Gbps compatible or higher), but IRISO has not given up on future products that overcome all these problems. However,
there are other methods to improve reliability besides the two-point contact method, so if you are considering both connection
stability and high-speed transmission, please contact us first.
Electrostatic Shielding/GND Terminal
What is electrostatic shielding?
Roughly speaking, electrostatic shielding is a method of surrounding an object through which an electrical signal flows with a metal object.
When an electric current flows through a place, a substance called induced current is generated in the nearby metal (conductor) in the opposite
direction to the direction in which the current is generated. The fact that the current flows means that an electromagnetic field is
generated around the current, but the electromagnetic field generated by the induced current has "directivity" that cancels out the
object that caused the current. Therefore, electrostatic shielding is a device that surrounds electronic devices and components with a
metal body to cancel out the electromagnetic field or noise generated inside. This has the same effect on noise coming in from the outside.
This includes metal casings of various devices and shielding layers applied to electric wires, and shielding layer products can also be
seen on the market on bags that wrap them.
Connector Electrostatic Shielding
Connectors are also attached to various products in the form of metal shells. IRISO has also released shielded BtoB connectors.
Differential transmission also has an effect, but the differential transmission effect is relatively good because there is a phenomenon called
"coupling" in the line, and the electric field tends to be close, but the effect is better in single-ended transmission where the electric field tends to diverge.
Electrostatic shield gap problem
By the way, there is a problem that also troubles us connector manufacturers. This is the problem of how to manage the shield gap.
For this type of in-machine connection type connector, there is inevitably a gap in the shield layer, especially in SMT mounting because
they are mounted on the board. In particular, if you want to visually check the solder state (rounded corners, etc.) without using X-rays, etc.,
you need to ensure a large amount of space. Electromagnetic field leakage occurs through this gap, and high frequencies with short wavelengths
in particular escape through narrow gaps, which may cause electrostatic shielding to lose its effectiveness first. In this case, it is better to
allocate the cost of shielding a single part to other measures (additional countermeasure parts, etc.). On the other hand, if combined with
a connection form such as BGA or press fitting, this gap can be narrowed, and gimmicks that even cover up SMT types have been designed
and commercialized. These options should be considered when matching them with the customer's actual manufacturing process and expected
costs. In addition, it is also necessary to consider whether the EMC characteristics of the entire device need to be improved, or whether measures
need to be taken to prevent self-poisoning (including interference with wireless modules, etc.).
Ground Terminal
The ground terminal is a terminal used for grounding/connecting electrostatic shields, etc. The figure on the right shows the terminal used to
ground the electrostatic shield (belt) of the FFC to the circuit board through the connector. This option includes connectors with more options
(multiple points of contact = ground terminal). This reduces ground resistance and does work for some customers.
(Although we have not yet commercialized it as a product) The pit structure seen in the mating part of the metal shell of the I/O cable has the
same purpose, aiming to reduce the ground resistance of the shield layer and increase the effect of the shielding performance. In addition to the
gap issue mentioned above, the question of how low the ground resistance can be made is also a factor in determining the performance of
electrostatic shielding.
Electrostatic shielding is an excellent and relatively inexpensive countermeasure in areas where it is expected to be effective. For EMC and
electrostatic shielding effectiveness, it is difficult to quantitatively evaluate the effectiveness of individual components, so IRISO has accumulated
expertise from customer feedback and evaluations by combining methods such as electromagnetic field analysis and close-range measurement.
We will continue our daily development work to resolve the above issues and to improve the "higher reliability" provided by electrostatic
shielding to an even higher level.