1. Strengthen the refined control of the storage environment
1. Temperature, humidity and cleanliness control
Temperature and humidity standards: The storage environment temperature should be controlled
at -10℃~40℃, and the humidity should be ≤60% RH to avoid oxidation of metal contacts and
aging of insulating materials due to moisture. A constant temperature and humidity warehouse
can be configured, and intelligent temperature and humidity sensors can be installed to monitor
in real time and link air conditioning and dehumidification equipment for adjustment.
Dust and corrosion prevention: The warehouse needs to be sealed and dustproof, and the floor
should be made of dustproof materials and cleaned regularly; for coastal or highly corrosive environments,
an air filtration system can be added to prevent salt spray, sulfide, etc. from corroding the plug plating
(such as gold plating and silver plating).
2. Anti-static and electromagnetic protection
Anti-static measures: Anti-static floors need to be laid in the storage area, and staff should wear anti-static
clothing and gloves; plugs should be stored in anti-static packaging bags or metal shielding boxes to prevent
static electricity from breaking through internal electronic components
(such as microwave devices of high-frequency connectors).
Electromagnetic shielding: For highly sensitive military aviation plugs, an electromagnetic shielding warehouse
can be set up to prevent external electromagnetic interference from affecting the electrical performance of the plug.
2. Standardize the warehousing and inventory management process
1. Strict warehousing acceptance standards
Performance testing: Perform appearance inspection (such as coating integrity, shell crack-free), electrical performance
test (insulation resistance, contact resistance), mechanical performance test
(plugging and unplugging force, locking structure reliability) on each batch of plugs, retain the test report and enter
it into the system.
Batch traceability management: Record the production batch, factory date, certificate number, technical documents
(such as drawings, test reports) of each batch of plugs, establish electronic files, and ensure that they can be traced back
to the production source and usage scenarios.
2. Scientific classification and inventory layout
Classification and storage principles:
Classification by use: such as aerospace, shipborne, land-based equipment, etc., partition storage to avoid mixing;
Classification by model and specification: Divide the area according to the interface size of the plug (such as M23, M50 series),
number of cores, and protection level (IP67/IP68), and clearly mark it;
First-in-first-out (FIFO) management: Through shelf identification and information system prompts, ensure that the plugs that
enter the warehouse first are shipped out first, reducing performance degradation caused by long-term inventory.